Three window units hum all summer, the kitchen and the back bedroom never cool, and the space heaters come out every January. You’d like one system for the whole house, and you want to know what it takes in a Marrero home.

Sweet Olive installs ducted air-source heat pumps in homes across Marrero and the rest of our service area, including houses that have never had ducts. A first system is a bigger job than a swap: the ducts, the return, the new circuits and the spot for the outdoor unit are all new decisions. So on the first visit we measure each room, look in the attic and under the floor, and check the panel. Your written estimate lays out the equipment, the duct layout, the electrical work and the Jefferson Parish permit steps.

If your house already has central air that is failing, the replacement page fits better. For a house with no system yet, new installation covers the full process.

Inside a first ducted heat pump in Marrero

Window units, space heaters and a raised floor with room underneath: why this Marrero installation keeps the equipment up in the attic.

Window air conditioners in the rear windows of a raised Marrero house
Location
Marrero, north of the Westbank Expressway
Home
Raised single-story frame house, about 1,300 sq ft, three bedrooms
System
Nominal 2-ton two-stage ducted heat pump
Ductwork
7 attic supply runs, 1 hall return, 2 jumper ducts
Electrical
Two new 240-volt circuits and a disconnect
Outdoor unit
Raised stand beside the rear steps
Project price
$10,950
Duration
4 working days

The house

Window units and a crawlspace

The house is a raised frame home in Marrero, north of the Westbank Expressway, about 1,300 square feet with three bedrooms. Three window units cool it, space heaters warm it, and it has never had ducts. The floor stands on piers with about thirty inches of open space underneath, and the attic is reached through a hatch in the hall ceiling.

The decision

Up in the attic, not under the floor

Ducts and an air handler under the floor are one option, and the crawlspace looks convenient. We put the equipment in the attic instead, because the space under the house is damp, tight to work in and the first place water reaches in a heavy storm, and heating and cooling equipment isn't built to sit in floodwater. The load calculation supports a nominal two-ton, two-stage system.

BedroomBedroomBedroomHallBathLivingKitchen
  • Dark circle, Each room: windows, sun and ceiling height for the load calculation
  • Ochre square, Attic opening: headroom and joists
  • Blue diamond, Return location: where a central return can draw air
  • Yellow triangle, Electrical panel: rating, open spaces and existing load
  • Open ring, Outdoor spot: footing and drainage
  • Dark cross, Thermostat: on an inside wall
The first visit in plan: the rooms, the attic opening, where a central return can draw air, the panel, the outdoor spot and the thermostat wall.

The work

Four days from hatch to startup

Day one widens the hall hatch within one joist bay, builds the attic platform and sets the air handler over a secondary pan with a float switch. Days two and three run seven insulated supply runs to ceiling registers, a central return in the hall ceiling and two jumper ducts from the back bedrooms, cutting each opening under dust sheeting. An electrician adds two 240-volt circuits and the disconnect while we set the outdoor unit on a stand beside the rear steps.

The result

Window units out, readings in

Day four runs the line set, the nitrogen pressure test and the evacuation, then the charge, airflow, static pressure and the drain. We set the thermostat and leave the readings. The window openings are closed back up, and the parish inspection follows. The aim is every room on one system, with the dry-out that comes from long, steady runs.

Attic or under the floor?

On a raised house, the first decision is where the equipment and the ducts live.

Attic

Air handler on a platform, ducts to ceiling registers, return in the hall ceiling.

  • Up out of reach of standing water
  • Needs a secondary pan and float switch
  • Headroom and hatch size decide the cabinet

Under the floor

Air handler and ducts in the space below, with floor registers.

  • Easier to reach some rooms
  • Damp, tight space to work and service
  • First place water reaches in a storm

Where the attic has room, we plan there first and keep the equipment off the ground.

Why we keep equipment up

Heating and cooling equipment isn’t built to sit in floodwater, and the space below a raised floor is where water arrives first. An attic air handler sits over a secondary drain pan with a float switch, so a blocked drain shuts the system off instead of staining a ceiling. The outdoor unit goes on a stand where the yard holds water, after we check the parcel’s requirement. The placement guide shows the options.

Returns that every room can reach

Each bedroom needs a way for its air to get back to the return, not just a supply register. We lay out a central return and add jumper ducts where closed doors would otherwise trap the air. The ductwork guide explains the layout.

Heat pump outdoor unit on a raised steel stand beside the side steps of a New Orleans cottage
An outdoor unit on a raised stand beside a raised house's steps.

Sizing a house that's never had central air

With no old nameplate to copy, the load calculation does all the work.

  • Dark circle, Air handler: on an attic platform, over a secondary drain pan
  • Ochre square, Supply runs: dropping to ceiling registers
  • Blue diamond, Central return: in the hall ceiling
  • Yellow triangle, Jumper duct: from a closed bedroom to the hall
  • Open ring, Line set and drain: along the outside wall
  • Dark cross, Outdoor unit: on a raised stand, with its disconnect
A first ducted system in section: attic air handler over its pan, ceiling registers, a hall return, a jumper duct and the outdoor unit on a stand.

Room by room

We run a room-by-room load calculation (ACCA Manual J) from your windows, walls, ceiling and air leaks, then lay out the ducts from those room loads. A house cooled by window units has no record of what a central system needs, and adding up the window units’ sizes doesn’t give one. Oversized equipment cools fast and leaves the air damp; the sizing guide explains why.

Backup heat for the cold snaps

Winters here are short, but cold mornings still come. A small electric heat strip in the air handler covers those hours and the defrost cycle, sized from your heating load rather than the largest strip the cabinet accepts.

The electrical side of a first system

  • The panel. Rating, open spaces and what already runs on it.
  • New circuits. One for the outdoor unit and one for the air handler’s heat strip, added by an electrician.
  • The disconnect. A shut-off within sight of the outdoor unit.
  • A panel upgrade. Only if the load check calls for it, and priced as its own line.

The electrical readiness guide covers the checks in more depth.

Technician servicing one of three rooftop heat pump units on a Mid-City building
A technician at an outdoor unit, the end of the new circuit and disconnect.

Permits in Marrero

Marrero is one of the larger West Bank communities, and it has no city government of its own.

Installing heating and cooling equipment in Marrero is filed with the Jefferson Parish Building Regulatory Division before the work, and inspected afterwards. Harvey to the east and Estelle to the south go to the same office; Westwego to the west is a separate city, so a Westwego address gets checked first. Your estimate states who obtains the permit, and the permit guide compares the offices. We confirm the electric account for the address at the same visit.

What a first system costs in Marrero

A first installation includes parts a replacement reuses, and the estimate shows each one.

Sweet Olive's typical range for a residential ducted heat pump installation is $4,250 to $11,750. We set your price after the site visit and write it into your estimate line by line, with the duct layout, new circuits and the Jefferson Parish permit steps shown separately.

Line on the estimate First installation Replacement
Supply and return ducts New, laid out from the room loads Tested; reused where sound
Ceiling or wall openings Cut for every register and grille Usually already there
Circuits and disconnect New Often reused after a check
Air handler platform and pan New Rebuilt if needed
Window units and openings Removed and closed as the estimate states Not applicable

What a first installation adds compared with a replacement, line by line.

The installation process guide walks through the work days, and the cost guide breaks a price into its parts. If you’re weighing a system without ducts, our ducted versus ductless guide explains why we install ducted systems.