Every heat pump carries a data plate: a printed label on the outdoor cabinet and another on the indoor air handler. Sweet Olive replaces and repairs ducted heat pumps across New Orleans, and a clear photo of both labels tells us the make, the capacity class, the refrigerant and the electrical data before anyone visits. You can read most of it yourself, without opening anything.

Labels on newer equipment also look different. Since January 1, 2023, the efficiency numbers come from a revised federal test, so a new unit’s label reads SEER2 and HSPF2 rather than SEER and HSPF. That change matters when you compare an old system with a replacement.

Where the labels are, and how to photograph them safely

Look and photograph from where you stand. Never remove a panel to find a label.

On the outdoor unit, the plate is usually on a side panel, often near the copper lines. On the indoor air handler, it is on the outside of the cabinet or its access door, in the closet, the attic or under the house. Use your phone’s flash, stand back far enough to get the whole plate in one frame, then take a second photo close enough to read the smallest line.

If the plate is faded or hidden behind a shrub, say so. Don’t move the unit or pull anything apart to reach it; we read it at the visit.

New matched heat pump outdoor unit on the same pad beside a Metairie ranch house
An outdoor unit on its pad: the data plate is on the cabinet side, often near where the copper lines connect.

The lines that matter

Makers lay the plate out differently, but these lines appear on almost every one.

Line on the plate What it tells us
Model number The product line and, on many brands, the nominal capacity: a 36 in the model often means 36,000 Btu per hour, or three tons
Serial number When it was built; each maker codes the date differently, and we decode it
Refrigerant and factory charge Which refrigerant the system uses and how much it left the factory with
Voltage and phase The supply the unit needs, usually 208 to 230 volts, single phase, in a house
Minimum circuit ampacity The smallest wire size the circuit can use
Maximum overcurrent protection The largest breaker or fuse allowed for the circuit
Compressor and fan amps Running and starting current, useful when a breaker trips or a motor struggles
Heat strip size (air handler) The backup electric heat, in kilowatts, which drives the indoor unit’s circuit

The main lines on a heat pump data plate and what each one tells us.

The electrical lines matter on a replacement: a new outdoor unit and heat strip may need a different circuit from the old ones. The components guide explains what each part does.

What changed on newer labels

Two changes show up on equipment built in the last few years.

14.3 SEER2

The national minimum cooling rating for split-system heat pumps manufactured on or after January 1, 2023, from the U.S. Department of Energy, with 7.5 HSPF2 for heating

A unit that met the old rules can’t be compared number for number with one rated under the new test. The revised test runs the equipment against more duct resistance, closer to a real house, so the same unit rates lower under SEER2 than it did under SEER.

The refrigerant line is changing too

Federal rules limit higher-impact refrigerants in new systems, so newer equipment often uses a different refrigerant from the R-410A on most older systems. The plate tells you which one. It matters for repairs, because parts and refrigerant have to match, and for replacements, because a new outdoor unit is paired with a matching indoor coil rather than connected to the old one.

What the label can't tell you

A data plate describes the box. It says nothing about the house the box is serving.

What the plate shows

Facts about the equipment as it left the factory.

  • Capacity class and model line
  • Refrigerant and factory charge
  • Electrical requirements
  • Efficiency ratings for the matched system

What only a visit shows

Facts about the system as it runs in your house.

  • Whether the capacity suits the rooms
  • Whether the ducts carry the air the unit needs
  • The charge and airflow today
  • Wear, corrosion and drain condition

Nominal tonnage on a plate is not proof of proper sizing; a room-by-room load calculation is.

New upright air handler in the same Woodmere hall closet, the gas line capped
An indoor air handler: its plate shows the heat strip and blower data the outdoor plate leaves out.

Matching the old tonnage is a tempting shortcut on a replacement, and it carries forward whatever mistake was made the first time. Our sizing guide explains the load calculation, and the staging comparison explains why two units of the same size can behave very differently. If the plate shows an older system that has started failing, the repair or replace guide helps you weigh the two.

Sending us the label

Four photos cover most first calls.

  • The outdoor unit’s data plate, whole and close up.
  • The indoor air handler’s data plate.
  • The electrical panel’s door label and breaker directory, with the cover left on.
  • The thermostat, so we can see the model and the screen.

Add them to your estimate request, along with the rooms that bother you. The estimate worksheet lists everything else worth collecting before a visit.